{"id":2840,"date":"2026-03-02T09:26:22","date_gmt":"2026-03-02T01:26:22","guid":{"rendered":"https:\/\/www.kms-hk.com\/?p=2840"},"modified":"2026-03-02T10:17:39","modified_gmt":"2026-03-02T02:17:39","slug":"%e9%ab%98%e4%bd%8e%e6%b8%a9%e4%ba%a4%e5%8f%98%e8%af%95%e9%aa%8c%e7%ae%b1%e3%80%90gdj%e7%b3%bb%e5%88%97%e3%80%91-2","status":"publish","type":"post","link":"https:\/\/www.kms-hk.com\/index.php\/en\/2026\/03\/02\/%e9%ab%98%e4%bd%8e%e6%b8%a9%e4%ba%a4%e5%8f%98%e8%af%95%e9%aa%8c%e7%ae%b1%e3%80%90gdj%e7%b3%bb%e5%88%97%e3%80%91-2\/","title":{"rendered":"High-Low Temperature Test Chamber"},"content":{"rendered":"<h5>Equipment structure<\/h5>\n<div><\/div>\n<div>The equipment is mainly composed of cabinet, refrigeration system, heating system, air circulation system and control system.<br \/>\nThe test box is perfectly designed, processed and formed by CNC machine tools, and adopts a non-reaction handle, which is easy to operate.<br \/>\nThe door seal is made of refined silicone rubber, so that there is no aging and hardening phenomenon at high and low temperatures.<br \/>\nThe inner liner is imported SUS304 stainless steel plate, and the shell is A3 plate spraying, which is more smooth and beautiful.<br \/>\nThe insulation system uses ultra-fine glass fiber or rigid polyurethane foam to fill the insulation area to ensure the temperature inside the cabinet.<br \/>\nThe independent heating and cooling system makes the equipment more effective in improving heating, cooling and efficiency.<br \/>\nThe refrigeration system is a fully automatic control and safety protection coordination system.<br \/>\nThe use of multi-wing type strong air supply circulation avoids any dead angles and can make the temperature distribution in the test area uniform.<br \/>\nThe air circulation outlet and return air design, the air pressure and air speed meet the test standards, and can make the temperature reheating time fast at the moment of opening the door.<\/div>\n<div><\/div>\n<div><strong>The temperature control adopts the &#8220;TEMI360&#8221; intelligent programmable controller imported from South Korea, 3.5 inch &#8220;TFT true color touch thin screen Chinese\/English optional menu, program editing: 120 sets of programs can be edited, each set of programs can edit 100 segments, communication interface RS485, the product display is clear and intuitive, the programmable control system is flexible and convenient to operate, the performance is stable, and the work is more efficient.<\/strong><\/div>\n<h5><strong><br \/>\n<img decoding=\"async\" src=\"\/\/www.kms-hk.com\/wp-content\/uploads\/20260107080635-695e140b7bf9f.jpg\" alt=\"\" border=\"0\" \/><br \/>\nThe equipment meets the standards<br \/>\n<\/strong><\/h5>\n<div><\/div>\n<div>GB\/T2423.1-2001 Basic Test Procedures for Electrical and Electronic Products Test A: Low temperature test method<br \/>\nGB\/T2423.2-2001 Basic Test Regulations for Electrical and Electronic Products Test B: High Temperature Test Method<br \/>\nGB2424.1-89 Basic environmental test regulations for electrical and electronic products Guidelines for high temperature and low temperature tests<br \/>\nGB\/T2324.2-1989.GB\/T2423.1-1989.GB\/T2423.4-1993 and other national standards<\/div>\n<div><\/div>\n<h5>Technical parameters<\/h5>\n<div><\/div>\n<div>\n<div>\n<table border=\"1\" width=\"1038\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"138\">model<\/td>\n<td width=\"108\"><strong>GDJ-50A(B\/C)<\/strong><\/td>\n<td width=\"104\"><strong>GDJ-100A(B\/C)<\/strong><\/td>\n<td width=\"115\"><strong>GDJ-150A(B\/C)<\/strong><\/td>\n<td width=\"113\"><strong>GDJ-250A(B\/C)<\/strong><\/td>\n<td width=\"113\"><strong>GDJ-500A(B\/C)<\/strong><\/td>\n<td width=\"118\"><strong>GDJ-800A(B\/C)<\/strong><\/td>\n<td width=\"111\"><strong>GDJ-1000A(B\/C)<\/strong><\/td>\n<td width=\"117\"><strong>GDJ-1500A(B\/C)<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"138\">Studio size: mm<\/td>\n<td width=\"108\">400\u00d7350\u00d7400<\/td>\n<td width=\"104\">500\u00d7450\u00d7500<\/td>\n<td width=\"115\">500\u00d7500\u00d7600<\/td>\n<td width=\"113\">600\u00d7520\u00d7800<\/td>\n<td width=\"113\">800\u00d7700\u00d7900<\/td>\n<td width=\"118\">800\u00d71000\u00d71000<\/td>\n<td width=\"111\">1000\u00d71000\u00d71000<\/td>\n<td width=\"117\">1500\u00d71000\u00d71000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"138\">Overall dimensions: mm<\/td>\n<td width=\"108\">820\u00d7710\u00d71400<\/td>\n<td width=\"104\">920\u00d7850\u00d71500<\/td>\n<td width=\"115\">920\u00d7850\u00d71670<\/td>\n<td width=\"113\">1020\u00d7870\u00d71870<\/td>\n<td width=\"113\">1260\u00d71100\u00d72040<\/td>\n<td width=\"118\">1280\u00d71480\u00d72030<\/td>\n<td width=\"111\">1420\u00d71390\u00d72200<\/td>\n<td width=\"117\">1980\u00d71480\u00d72200<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"138\">Voltage\/power<\/td>\n<td width=\"108\">A\uff1a220V\/2KW<br \/>\nB\uff1a220V\/2.5KW<br \/>\nC\uff1a220V\/4KW<\/td>\n<td width=\"104\">A\uff1a220V\/2.5KW<br \/>\nB\uff1a380V\/3.5KW<br \/>\nC\uff1a380V\/4.5KW<\/td>\n<td width=\"115\">A\uff1a220V\/3KW<br \/>\nB\uff1a380V\/4KW<br \/>\nC\uff1a380V\/5KW<\/td>\n<td width=\"113\">A\uff1a220V\/3.5KW<br \/>\nB\uff1a380V\/4.5KW<br \/>\nC\uff1a380V\/5.5KW<\/td>\n<td width=\"113\">A\uff1a220V\/4KW<br \/>\nB\uff1a380V\/6KW<br \/>\nC\uff1a380V\/8KW<\/td>\n<td width=\"118\">A\uff1a220V\/4.5KW<br \/>\nB\uff1a380V\/6.5KW<br \/>\nC\uff1a380V\/8.5KW<\/td>\n<td width=\"111\">A\uff1a220V\/5KW<br \/>\nB\uff1a380V\/7KW<br \/>\nC\uff1a380V\/9KW<\/td>\n<td width=\"117\">A\uff1a380V\/7KW<br \/>\nB\uff1a380V\/9KW<br \/>\nC\uff1a380V\/12KW<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"50\">Technology<br \/>\nParameters<\/td>\n<td width=\"88\">Temperature range<\/td>\n<td colspan=\"8\" width=\"900\">A:-20\u2103\uff5e+150\u2103\/ B: -40\u2103\uff5e+150\u2103\/ C: -70\u2103\uff5e+150\u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"88\">Fluctuation\/uniformity<\/td>\n<td colspan=\"8\" width=\"900\">\u2264\u00b10.5\u2103\/\u22642\u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"88\">Rate of warming<\/td>\n<td colspan=\"8\" width=\"900\">1.0\uff5e3.0\u2103\/min<\/td>\n<\/tr>\n<tr>\n<td width=\"88\">Cooling rate<\/td>\n<td colspan=\"8\" width=\"900\">0.7\uff5e1.0\u2103\/min<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"50\">box<br \/>\nMaterials<\/td>\n<td width=\"88\">Outer carton material<\/td>\n<td colspan=\"8\" width=\"900\">A3 steel plate electrostatic spraying\/SUS304 stainless steel matte line hairline treatment<\/td>\n<\/tr>\n<tr>\n<td width=\"88\">Inner box material<\/td>\n<td colspan=\"8\" width=\"900\">Imported SUS304 stainless steel plate<\/td>\n<\/tr>\n<tr>\n<td width=\"88\">Insulation<\/td>\n<td colspan=\"8\" width=\"900\">Microfiberglass insulation cotton\/rigid polyurethane foam<\/td>\n<\/tr>\n<tr>\n<td width=\"88\">The box door is sealed<\/td>\n<td colspan=\"8\" width=\"900\">Double-layer high, low temperature anti-aging and hardening refined silicone sealing strips<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\" width=\"50\">Hot and cold<br \/>\nexchange<br \/>\nsystem<\/td>\n<td rowspan=\"2\" width=\"88\">controller<\/td>\n<td colspan=\"8\" width=\"900\">Controller: &#8220;TEMI360&#8221; intelligent programmable controller imported from South Korea<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" width=\"900\">Accuracy range: temperature \u00b10.1\u00b0C, indication accuracy: temperature \u00b10.1\u00b0C, resolution: \u00b10.1\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"88\">Temperature sensor<\/td>\n<td colspan=\"8\" width=\"900\">Platinum resistor PT100\u03a9\/MV<\/td>\n<\/tr>\n<tr>\n<td width=\"88\">circulatory system<\/td>\n<td colspan=\"8\" width=\"900\">Temperature-resistant and low-noise motor, single-cycle, extended shaft, stainless steel multi-blade centrifugal blade<\/td>\n<\/tr>\n<tr>\n<td width=\"88\">Heating method<\/td>\n<td colspan=\"8\" width=\"900\">Nichrome alloy electric heating heater<\/td>\n<\/tr>\n<tr>\n<td width=\"88\">Refrigeration method<\/td>\n<td colspan=\"8\" width=\"900\">Unit cooling method \/ dual (stacked) cooling method (air cooling)<\/td>\n<\/tr>\n<tr>\n<td width=\"88\">cooler<\/td>\n<td colspan=\"8\" width=\"900\">French &#8220;Taikang&#8221; multi-stage diaphragm evaporator<\/td>\n<\/tr>\n<tr>\n<td width=\"88\">Compressor<\/td>\n<td colspan=\"8\" width=\"900\">French &#8220;Taikang&#8221; fully enclosed refrigeration compressor \/ French &#8220;Taikang&#8221; fully enclosed refrigeration compressor unit<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"138\">Timing function<\/td>\n<td colspan=\"8\" width=\"900\">0.1\uff5e99.99\uff08S\u3001M\u3001H\uff09<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"138\">Security devices<\/td>\n<td colspan=\"8\" width=\"900\">Power overload, leakage, grounding, over-temperature protection (with audible prompt), fast fuse, compressor over-voltage protection<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"138\">Standard configuration<\/td>\n<td colspan=\"8\" width=\"900\">High and low temperature resistant tempered glass internal heating insulating glass observation window: 220\u00d7180 (mm) one, one light, one test lead hole \u00a250mm, two sample holders, with casters<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"138\">Supply voltage<\/td>\n<td colspan=\"8\" width=\"900\">AC\u00f8220V\u00b750HZ\/380V\u00b750HZ<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"138\">Use ambient temperature<\/td>\n<td colspan=\"8\" width=\"900\">15\u2103\uff5e\uff0b30\u2103 \u226485\uff05R.H<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Optional accessories<\/td>\n<td colspan=\"8\" width=\"900\">&#8220;TEMI880&#8221; programmable touch screen (optional, additional charge upon order)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Note: 1. &#8220;GDJ&#8221; is the model of high and low temperature alternating test chamber.<br \/>\n2. The technical parameters are measured at the ambient temperature \u226425\u00b0C.<br \/>\n3. The above is a standard test chamber, which can be customized according to the specific requirements of users.<br \/>\n4. Non-standard &#8220;high and low temperature alternating laboratory&#8221; can be customized according to the specific requirements of users.<br \/>\n5. The height of the overall dimension does not include the height of the casters at the bottom of the box.<\/p>\n<p><strong>Reference Figure:<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" title=\"\" src=\"\/\/www.kms-hk.com\/wp-content\/uploads\/20260107080635-695e140b8a843.jpg\" alt=\"\" width=\"600\" height=\"600\" \/><img loading=\"lazy\" decoding=\"async\" title=\"\" src=\"\/\/www.kms-hk.com\/wp-content\/uploads\/20260107080636-695e140c535b8.jpg\" alt=\"\" width=\"600\" height=\"600\" \/><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The equipment is suitable for the adaptability test of instrumentation materials, electricians, electronic products, household appliances, automobile and motorcycle parts, chemical coatings, various electronic components and other related product parts in the storage, transportation and use of high and low temperature environments. This test equipment is mainly used for environmental simulation testing of the physical and other related characteristics of the product under low temperature, high temperature and user requirements, and after the test, through testing, to judge the performance of the product, whether it can still meet the predetermined requirements, so as to facilitate product design, improvement, appraisal and factory inspection.<\/p>\n","protected":false},"author":1,"featured_media":1831,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[190,86],"tags":[],"class_list":["post-2840","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-high-low-temperature-test-chamber","category-products2"],"_links":{"self":[{"href":"https:\/\/www.kms-hk.com\/index.php\/wp-json\/wp\/v2\/posts\/2840","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kms-hk.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kms-hk.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kms-hk.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kms-hk.com\/index.php\/wp-json\/wp\/v2\/comments?post=2840"}],"version-history":[{"count":6,"href":"https:\/\/www.kms-hk.com\/index.php\/wp-json\/wp\/v2\/posts\/2840\/revisions"}],"predecessor-version":[{"id":2874,"href":"https:\/\/www.kms-hk.com\/index.php\/wp-json\/wp\/v2\/posts\/2840\/revisions\/2874"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kms-hk.com\/index.php\/wp-json\/wp\/v2\/media\/1831"}],"wp:attachment":[{"href":"https:\/\/www.kms-hk.com\/index.php\/wp-json\/wp\/v2\/media?parent=2840"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kms-hk.com\/index.php\/wp-json\/wp\/v2\/categories?post=2840"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kms-hk.com\/index.php\/wp-json\/wp\/v2\/tags?post=2840"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}