Product Features:
The high and low temperature cold and hot shock test chamber adopts the structure of vertical box and cold and hot box, and adopts the method of carrying the basket to convert the test area where the test product is located to achieve the purpose of cold and hot shock test. This structure reduces the heat load during cold and hot shock, shortens the temperature recovery time, and is a way of cold and hot shock.
Technical features:
1. Use refrigerants such as R404a, R23.
2. The basket can be moved from one box to another within 10 seconds.
3. In the process of cold and heat conversion of impact test, it can quickly return to normal temperature and remain stable, and the influence of air convection and heat radiation on temperature in the box is avoided through technical treatment.
4. The scientific air convection system can ensure the uniform distribution of air in the box.
5. Equipped with imported Chinese touch screen controller, the parameters of the cyclic test can be set in advance, so that it can automatically complete the whole process of the test, which is convenient to use.
6. Control dwell and changeover time are adjustable.
7. When the impact test is not done, a single box can be used for temperature change test, and one box can be used for three purposes.
2. The basket can be moved from one box to another within 10 seconds.
3. In the process of cold and heat conversion of impact test, it can quickly return to normal temperature and remain stable, and the influence of air convection and heat radiation on temperature in the box is avoided through technical treatment.
4. The scientific air convection system can ensure the uniform distribution of air in the box.
5. Equipped with imported Chinese touch screen controller, the parameters of the cyclic test can be set in advance, so that it can automatically complete the whole process of the test, which is convenient to use.
6. Control dwell and changeover time are adjustable.
7. When the impact test is not done, a single box can be used for temperature change test, and one box can be used for three purposes.
Reference Standards:
GB/T 2423.1-2001 Electrical and electronic products environmental test test A: low temperature GB/T 2423.2-2001 Electrical and electronic product environmental test test B: high temperature GB10592-2008, GJB150.3
Product Usage Requirements:
1. Equipment placement space requirements: Ambient temperature: The placement site should be ventilated, or equipped with air conditioning equipment, to ensure that the surrounding ambient temperature is within 0~30°C after the equipment is started. Site requirements: flat, ventilated (temperature accumulation cannot be formed at the equipment exhaust outlet), and the exhaust side of the equipment is more than 1.5 meters away from the wall. There is no vibration around the equipment placement, no direct sunlight or direct radiation from other heat sources. Air quality: No high concentration of dust and corrosive gases, and cannot be tested and stored in flammable and explosive gases. Relative humidity: less than 85% R.H
2. Space location: In order to facilitate ventilation and operation and maintenance, there should be space for the box door to open and close normally at the opening door of the equipment.
3. Equipment power supply: meet the power supply requirements of the corresponding model.
2. Space location: In order to facilitate ventilation and operation and maintenance, there should be space for the box door to open and close normally at the opening door of the equipment.
3. Equipment power supply: meet the power supply requirements of the corresponding model.
Technical data sheet:
|
model
|
HSTCE-60
|
HSTCE-180
|
HSTCE-300
|
HSTCE-500
|
||
|
The size of the high and low temperature zone (depth, width and height) cm
|
40×40×45
|
55×55×60
|
65×65×70
|
80×80×80
|
||
|
Basket size (depth, width and height) cm
|
20×20×20
|
28×28×28
|
35×35×35
|
45×45×45
|
||
|
Overall dimensions (depth, width, height) cm
|
172×105×152
|
186×120×179
|
198×130×199
|
206×145×220
|
||
|
Ambient temperature requirements
|
Vertical hatchback
|
|||||
|
Sexual performance parameters
|
Sample area
|
Exposure temperature range
|
A:-20℃~180℃; B:-40℃~180℃ ; C:-60℃~180℃
|
|||
|
Temperature deviation
|
±3.0℃
|
|||||
|
Uniform/fluctuating temperature
|
±2°C/±0.5°C (constant temperature)
|
|||||
|
Recovery time
|
5 minutes (the temperature reaches the original temperature value)
|
|||||
|
Recovery conditions
|
Under no-load conditions, the exposure temperature is 30 minutes each; Temperature detector location: air outlet.
|
|||||
|
Sample quality
|
10kg
|
15kg
|
25kg
|
35kg
|
||
|
High temperature zone
|
High temperature
|
230℃
|
||||
|
Heating time
|
Room temperature ~230°C within 35 minutes
|
|||||
|
Low temperature zone
|
Low temperature
|
A:-40℃; B:-60℃; C:-70℃;
|
||||
|
Cooling time
|
A: 50 minutes; B: 80 minutes; C: 100 minutes;
|
|||||
|
Control system
|
controller
|
Programmable temperature controller, 7-inch true color LCD touch screen input, Chinese menu, PID self-tuning, data recording function, support USB computer connection function, curve display function, etc., easy to operate.
|
||||
|
Control precision
|
Setting accuracy: temperature 0.1°C, indication accuracy: temperature 0.1°C
|
|||||
|
Temperature sensor
|
K-type temperature sensor
|
|||||
|
Timing function
|
Any setting
|
|||||
|
Material and structural characteristics
|
Shell
|
Cold-rolled steel plate production, corner arc and integrated plane design, beautiful appearance.
|
||||
|
The box is rust-proof
|
Anti-rust pretreatment before spraying, and then electrostatic spraying, excellent anti-rust function.
|
|||||
|
Linger
|
SUS304/2B stainless steel plate, the inner liner adopts arc design, easy maintenance.
|
|||||
|
Insulation
|
Ultra-fine glass wool or polyurethane foam.
|
|||||
|
Motor heat dissipation
|
The cabinet is specially deepened, with axial fan ventilation, which greatly improves the heat dissipation of the motor.
|
|||||
|
heater
|
Customized stainless steel fin electric heating pipe for uniform heat dissipation and long service life.
|
|||||
|
Observation window
|
Hollow conductive film electric heating defrost observation window.
|
|||||
|
Sealed
|
Customized silicone sealing strips made of molds, and special defrosting devices are set up at the door frame.
|
|||||
|
Blowers
|
Centrifugal impeller and asynchronous motor
|
|||||
|
Test frame
|
304 stainless steel is finely welded
|
|||||
|
Lifting transmission
|
Special lead cylinder, with solenoid valve, to realize the displacement of the gondola.
|
|||||
|
Refrigeration system
|
Compressor
|
The original imported French “Taikang” fully enclosed refrigeration compressor is equipped with a compressor condensate receiver.
|
||||
|
Refrigeration method
|
Mechanically compressed laminated cooling, air-cooled or water-cooled.
|
|||||
|
Condenser
|
Fin type radiator, high-quality external rotor motor;
|
|||||
|
Refrigerant
|
R23\R404A refrigerant;
|
|||||
|
Other accessories
|
Filters, expansion valves, main solenoid valves, etc. are imported high-quality accessories.
|
|||||
|
Safety device
|
Power leakage protection, motor overload protection, compressor overvoltage, overheating, overcurrent protection, lack of phase protection, equipment safety grounding protection terminal, over-temperature protection.
|
|||||
|
Standard equipment
|
2 ф50mm cable holes, universal pulley and fixed support structure, 2 observation windows, and 2 window lights.
|
|||||
|
Optional accessories
|
Special sample holders; temperature recorder; Oil film brushed special treatment all-stainless steel shell.
|
|||||
|
Remarks
|
1. Model description: “HSTCE” indicates and presents “hot and cold shock test chamber (hatchback)”; “60” indicates the approximate volume of the box; “A\B\C” indicates that the low temperature of low temperature exposure is -20°C, -40°C, and -60°C. 2. The above data parameters are no-load of the equipment and measured at the ambient temperature of 25°C. 3. The size of the inner cavity of the equipment can be customized according to customer requirements. 4. If there is any change in this technical information without prior notice, the actual configuration is subject to the technical agreement signed by both parties.
|
|||||
Images:


.jpg)